About Us
Connecting the Southeast With Reliable Technology
For more than 10 years, we have provided dependable Communications solutions for businesses and facilities throughout the Southeast. Our team combines real-world field experience with a practical, customer-first approach, delivering systems that are designed correctly, installed professionally, and built to perform long term.
Specialized Wireless Coverage Experience
Reliable communication inside a building is no longer optional. We bring years of experience designing and installing Public Safety BDA/ERRCS systems that help first responders maintain critical radio coverage when it matters most. We also have more than 10 years of experience with cellular DAS solutions, improving indoor cellular coverage for employees, tenants, customers, and visitors.
Proven Across the Southeast
Our work can be found in projects throughout the Southeast, serving a range of commercial, industrial, healthcare, education, hospitality, and multi-use facilities. Whether the need is stronger cellular service, public-safety radio coverage, structured IT infrastructure, or an integrated communications solution, we tailor every project to the building, the jurisdiction, and the people who rely on it.
Our Commitment
We believe in straightforward communication, quality workmanship, and solutions that hold up beyond installation day. From initial site assessment and system design through installation, testing, documentation, and support, we work to make complex technology simple and dependable for our clients.
Meet The Owner
Paul Erickson
Paul Erickson is a communications professional with a wide range of experience in the telecommunications and radio frequency (RF) fields, such as technical writing, design, project management and system installation/integration. His is scope of expertise includes in-building 4 & 5G Cellular DAS, Public Safety ERCES, in-building 4G Cellular, WAN, 4 & 5G in-vehicle cellular communications deployment, LAN (wired & wireless) and complex audio-visual systems.
Lead Technician
Gunnar Erickson
Experience
Operation and repair of cellular and HF RF transceivers (Kenwood, Motorola, Apple, Samsung etc)
Design, construction, installation and testing of RF antenna systems for multi frequency-band applications.
Design, installation, testing and commissioning of in-building 4G & 5G cellular DAS
Design, installation, testing and commissioning of Public Safety ERCES
Strong understanding of FCC, NFPA, IFC and SC Fire Code ERCES requirements
Installation and testing of Fleet Public Safety in-vehicle cellular router and antenna systems – Municipalities and Commercial
Installation, termination and RF testing of various coaxial cable types (LMR400/600/Heliax) and connectors
Installation, termination and testing of category cable
Installation and testing of audiovisual systems
Configuration and monitoring of cellular router and cellular hybrid DAS platforms
Performing RF site surveys for cellular and public safety DAS applications using spectrum analyzers and other application specific test equipment
Project management of in-building cellular BDA, cellular hybrid DAS and Public Safety ERCES installations
System Acceptance testing, configuration and optimization of cellular DAS and Public Safety ERCES.
Technical Writing – Work Scopes, Inspection, Testing and Process Procedures
Skill Set/Knowledge/Abilities
Consulting and Project Management
Initial RF Site Surveys and Testing (public safety and cellular)
In-building system design and installation RF (public safety and cellular)
In-building system configuration, optimization and commissioning of Public Safety ERCES and cellular DAS
Antenna design, construction, installation and acceptance testing RF (HF)
Fleet vehicle and in-building cellular LAN installation, configuration and activation (Cradlepoint/Sierra Wireless etc) including IoT
Structured cabling (CAT5 & CAT6)
Installation and testing of wireless access points (WAP) and RF server antennas
Test Equipment – Spectrum Analyzers, Vector Network Analyzer, Signal
Generators, RF, low and high voltage
Technical Writer – ERCES SOW, Naval Nuclear and Commercial Nuclear
Quality Assurance projects
Understanding and application of IFC510, NFPA 72, NFPA 1221 and NFPA
1225 as related to ERCES
Certifications:
◦ Comba RF101 and V3 NG Public Safety BDA Fiber DAS
◦ Nextivity Cel-Fi Shield (Public Safety ERCES) - Installer/Integrator
◦ Nextivity Cel-Fi Quatra Family (4000c, GO, 1000) Cellular Installer/
Integrator
◦ FCC GROL holder
FCC Registration Number: 0038028999
FCC Serial Number: PG0008033
◦ Safer Buildings Coalition (SBC) ERCES training - 10 hrs
Experience
Operation of cellular and HF RF transceivers (Kenwood, Motorola, Apple, Samsung etc)
Design, construction, installation and testing of RF antenna systems for multi frequency-band applications.
Design, installation, testing and commissioning of in-building 4G & 5G cellular DAS
Design, installation, testing and commissioning of Public Safety ERCES
Understanding of FCC, NFPA, IFC and SC Fire Code ERCES requirements
Installation and testing of Fleet Public Safety in-vehicle cellular router and antenna systems – Municipalities and Commercial
Installation, termination and RF testing of various coaxial cable types (LMR400/600/Heliax) and connectors
Installation, termination and testing of category cable
Configuration and monitoring of cellular router and cellular hybrid DAS platforms
Performing RF site surveys for cellular and public safety DAS applications using spectrum analyzers and other application specific test equipment
System Acceptance testing, configuration and optimization of cellular DAS and Public Safety ERCES.
Skill Set/Knowledge/Abilities
Initial RF Site Surveys and Testing (public safety and cellular)
In-building system design and installation RF (public safety and cellular)
In-building system configuration, optimization and commissioning of Public Safety ERCES and cellular DAS
Antenna design, construction, installation and acceptance testing RF (HF)
Fleet vehicle and in-building cellular LAN installation, configuration and activation (Cradlepoint/Sierra Wireless etc) including IoT
Structured cabling (CAT5 & CAT6)
Test Equipment – Spectrum Analyzers, Vector Network Analyzer, Signal
Generators, RF, low and high voltage
Certifications:
◦ Comba RF101 and V3 NG Public Safety BDA Fiber DAS
◦ Bachelors In Business Administration at Newberry College
◦ Nextivity Cel-Fi Shield (Public Safety ERCES) - Installer/Integrator
◦ Nextivity Cel-Fi Quatra Family (4000c, GO, 1000) Cellular Installer/
Integrator
◦ Safer Buildings Coalition (SBC) ERCES training - 5 hrs
TD Bank Greenville, SC Campus Building A
Public Safety ERCES – SC Palmetto 800 Network
Building Details – 4 Story Office building including penthouse, full basement and connecting tunnel – 175,000 sq.ft.
Solution: Nextivity Cel-Fi Quatra Red ERCES and Shield Extend Upgrade
Role: Project Manager Systems Integrator
Nissin Foods, USA Piedmont, SC Production Facility
Public Safety ERCES – SC Palmetto 800 Network
Building Details – Multi-Level Food Production Facility - 750,000 sq. ft. of facility coverage.
Solution: Comba Class, A, V3 NG Public Safety BDA Fiber DAS
Role: AHJ & State FCC licensee coordinator, Design, Project Manager and Integrator.
Recent Projects
TD Bank Greenville, SC Campus Building B
Public Safety ERCES – SC Palmetto 800 Network Building Details – 4 Story Office building including penthouse - 140,000 sq.ft.
Solution: Nextivity Cel-Fi Quatra Red ERCES and Shield Extend Upgrade
Role: Project Manager Systems Integrator
Novant Health, Greenville, SC Buildings A & C
Public Safety ERCES – SC Palmetto 800 Network
Building Details - 4 Story Office building including penthouse, full basement and connecting tunnel & 2 Story Office building including lower level and tunnel – 250,000 sq.ft.
Solution: Nextivity Cel-Fi Shield Extend ERCES Upgrade
Role: Project Manager Systems Integrator
TD Bank Greenville, SC Campus Building C
Public Safety ERCES – Palmetto 800 Network
Building Details – 2 Story Office building including lower level and tunnel -75,000 sq.ft.
Solution: Nextivity Cel-Fi Quatra Red ERCES & Shield Extend Upgrade
Role: Project Manager Systems Integrator
Novant Health, Greenville, SC Building B
Public Safety ERCES – SC Palmetto 800 Network
Building Details – 4 Story Office building including penthouse - 140,000 sq.ft.
Solution: Nextivity Cel-Fi Shield Extend ERCES Upgrade
Role: Project Manager & Systems Integrator